SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ahlström Håkan)
 

Sökning: WFRF:(Ahlström Håkan) > Ortiz Nieto Francisco > Jorulf Håkan > MR spectroscopy of ...

MR spectroscopy of the human prostate using surface coil at 3 T : Metabolite ratios, age-dependent effects, and diagnostic possibilities

Weis, Jan (författare)
Uppsala universitet,Enheten för radiologi
Jorulf, Håkan (författare)
Uppsala universitet,Enheten för radiologi
Bergman, Antonina (författare)
Uppsala universitet,Enheten för radiologi
visa fler...
Ortiz-Nieto, Francisco (författare)
Uppsala universitet,Enheten för radiologi
Häggman, Michael (författare)
Uppsala universitet,Urologkirurgi
Ahlström, Håkan (författare)
Uppsala universitet,Enheten för radiologi
visa färre...
 (creator_code:org_t)
2011-09-23
2011
Engelska.
Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1053-1807 .- 1522-2586. ; 34:6, s. 1277-1284
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: To measure prostate spectra of healthy volunteers using a surface coil, to demonstrate age-dependent effects, and to investigate diagnostic possibilities for prostate cancer detection. MATERIALS AND METHODS: Single-voxel and 2D magnetic resonance spectroscopic imaging (MRSI) spectra of 51 healthy volunteers with biopsy-proven prostate carcinoma of 20 patients for comparison were measured and processed using the LCModel. The mean normalized spectra and mean metabolite-to-citrate intensity ratios were computed. RESULTS: Metabolite-to-citrate ratios of healthy volunteers were lower in the older group (>51 years) than in the younger group (<45 years). The peripheral zone (PZ) revealed a lower metabolite-to-citrate intensity ratio than the central gland (CG). Age-related differences in metabolite-to-citrate ratio were insignificant in the voxels with predominantly CG tissue, whereas significant differences were found in the PZ. Sensitivity in detecting prostate cancer by single-voxel spectroscopy (SVS) and 2D MRSI was 75% and 80%, respectively. CONCLUSION: SVS and 2D MRSI of the prostate at 3 T, using a surface coil, are useful in situations when insertion of the endorectal coil into the rectum is difficult or impossible. Our findings of age-dependent effects may be of importance for the analysis of patient spectra.

Nyckelord

single-voxel spectroscopy
spectroscopic imaging
prostate cancer
3 Tesla
LCModel
surface coil

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy